Outcome | Compliant |
4 violations cited :
Code 4-501.114
Chlorine solution concentration below 100 ppm
FULL FOOD CODE:
A chemical SANITIZER used in a SANITIZING solution for a manual or mechanical operation shall meet these limits or as otherwise approved: (P) Chlorine ppm pH<10 pH<8 25 120 F 120 F 50 100 F 75 F 100 55 F 55 F Iodine a concentration of between 12.5 and 25 ppm and minimum temp of 75 F and pH of 5 or less or meets manufacturer's specifications. (P) Quats minimum temperature of 75 F, hardness of 500 ppm or less and meet manufacturers use directions. (P)
A chemical SANITIZER used in a SANITIZING solution for a manual or mechanical operation shall meet these limits or as otherwise approved: (P) Chlorine ppm pH<10 pH<8 25 120 F 120 F 50 100 F 75 F 100 55 F 55 F Iodine a concentration of between 12.5 and 25 ppm and minimum temp of 75 F and pH of 5 or less or meets manufacturer's specifications. (P) Quats minimum temperature of 75 F, hardness of 500 ppm or less and meet manufacturers use directions. (P)
Priority
Corrected on 1-05-2024
Code 4-301.12
Two compartment sink not approved for use
FULL FOOD CODE:
(A) Except as specified in ¶ (C) of this section, a sink with at least 3 compartments shall be provided for manually washing, rinsing, and SANITIZING EQUIPMENT and UTENSILS. (Pf) (B) Sink compartments shall be large enough to accommodate immersion of the largest EQUIPMENT and UTENSILS. If EQUIPMENT or UTENSILS are too large for the WAREWASHING sink, a WAREWASHING machine or alternative EQUIPMENT as specified in ¶ (C) of this section shall be used. (Pf) (C) Before a 2-compartment sink is used the PERMIT HOLDER shall have its use APPROVED. (D) A 2-compartment sink may not be used for WAREWASHING operations where cleaning and SANITIZING solutions are used for a continuous or intermittent flow of KITCHENWARE or TABLEWARE in an ongoing WAREWASHING process.
(A) Except as specified in ¶ (C) of this section, a sink with at least 3 compartments shall be provided for manually washing, rinsing, and SANITIZING EQUIPMENT and UTENSILS. (Pf) (B) Sink compartments shall be large enough to accommodate immersion of the largest EQUIPMENT and UTENSILS. If EQUIPMENT or UTENSILS are too large for the WAREWASHING sink, a WAREWASHING machine or alternative EQUIPMENT as specified in ¶ (C) of this section shall be used. (Pf) (C) Before a 2-compartment sink is used the PERMIT HOLDER shall have its use APPROVED. (D) A 2-compartment sink may not be used for WAREWASHING operations where cleaning and SANITIZING solutions are used for a continuous or intermittent flow of KITCHENWARE or TABLEWARE in an ongoing WAREWASHING process.
Priority Foundation
Corrected on 1-11-2024
Code 4-302.14
Expand for full food code definition
FULL FOOD CODE:
A test kit or other device that accurately measures the concentration in mg/L of SANITIZING solutions shall be provided. (Pf)
A test kit or other device that accurately measures the concentration in mg/L of SANITIZING solutions shall be provided. (Pf)
Priority Foundation
Corrected on 1-11-2024
Code 6-202.14
Toilet room(s) not provided with self closing door
FULL FOOD CODE:
Except as otherwise allowed, a toilet room located on the PREMISES shall be completely enclosed and provided with a tight-fitting and self-closing door.
Except as otherwise allowed, a toilet room located on the PREMISES shall be completely enclosed and provided with a tight-fitting and self-closing door.
Core
Not corrected